0 5-1ton Industrial oil steam boiler
After electric 0 5-1ton industrial steam boiler shutdown, how to carry out maintenance in the long-term disabled electric steam boiler, furnace should pay great attention to external corrosion and maintenance problems. First, after power shutdown cooling steam boiler, the ash must be thoroughly cleaned and the heating surface fouling the upper grate, the lower portion of the furnace. Then to maintain a certain degree of natural ventilation flue. In general, in order desiccant moisture should be placed in the furnace, flue. The quicklime as a drying agent, within the furnace or flue gas per cubic meter should be placed generally about 3kg. After placing all the ventilation should be tightly closed doors. After the change of lime powder to be replaced. Low-lying position as boiler room, ground during shutdown severe flood tide, often approach should be used and placed a small fire to dry desiccant combination. If the boiler shutdown a long time, after the complete removal of soot coated with an anti-corrosion red lead paint in oil or other metal surface furnace. As for anti-corrosion maintenance methods inside the furnace shutdown, the shutdown Yaoan the length of time to be. In general, no more than one month shutdown maintenance wet available, more than one month should be taken to maintain dry. To note the following problems when a dry maintenance: desiccant boiler not in direct contact with the metal surface, may be mounted in a container such as the iron plate after the desiccant is placed, and a hole for shutting the other hand hole cover, valve steam, the water pipe change must cut lime powder should be replaced.
8 ton condensing fuel gas-fired boilers in Russia
ZG boiler re-export project—a full set of 8 tons of condensing fuel gas-fired boilers was exported to St. Petersburg, Russia. As the economic power of Russia, St. Petersburg takes industry as the main development point, and is a highly developed international city of science, technology and industry. Therefore, the selection requirements for production equipment are very high. The ZG boiler oil and gas boilers feature the internationally popular classic “all-wet-back three-return” design structure, FRG flue gas recirculation, condensation prevention and control, and other special technical advantages to enable Russian customers to successfully sign a complete set of 8 tons of WNS with ZG boiler within a week. Type saturated steam boiler contract, the fuel is natural gas and diesel. In addition, based on Europe's strict boiler emission standards, ZG boiler has configured pure Italian imported burners for customers.
Use should pay attention to the problem of 0 5-1ton industrial steam boiler pressure gauge. Rated steam pressure of less than 2.45MPa steam boiler, a manometer accuracy no less than 2.5; equal to the rated boiler steam pressure 2.45MPa, the pressure is not less than 1.5. Dial gauge diameter of not less than 100 mm, to ensure that the operator can clearly see the surface pressure indication. 2. Steam boiler gauge plate should draw a red line that indicates the maximum allowable working pressure. 3. The steam boiler pressure gauge should be installed in place to facilitate the observation and purged, and should prevent high temperature, vibration and icing. 4. The steam boiler pressure gauge should be checked at least once every six months, after calibration seal should be sealed. 5. The steam boiler gauge connection tube not leak water and steam, otherwise it will reduce the pressure instruction value. Biomass boiler is a kind of boiler to biomass energy as a boiler fuel called biomass boilers, steam boilers into biomass, biomass hot water boiler, biomass stove, biomass thermal oil heaters, vertical raw biomass boilers, biomass boilers and other horizontal. Steam boiler is an energy conversion device, the energy input to the boiler fuel chemical energy, electrical energy, thermal energy and other forms of high temperature flue gas, and after converting the boiler, the steam output having a certain outside thermal energy, high-temperature hot water or an organic carrier. 6. A steam boiler pressure gauge measuring range should be compatible with the operating pressure of the device under test, the working pressure is generally 1.53 times, preferably 2 times the working pressure. Steam boiler no pressure gauge, pressure gauge or pressure gauge damage does not meet the requirements. When the steam boiler pressure gauge of the following circumstances, should stop using: 1, the surface of the glass broken or blurred dial; 2, lead-free seal, lead seal is broken or exceeds the calibration cycle; 3. When no pressure gauge pointer position is limited to the limit staple nail can not be restored, and the unlimited gauge pointer from zero rank bit data is out of range pressure layer. Difference; 4, leak or pointer jump table; 5, other defects affect the gauge accuracy.
Provide for the growers Kingenta Ecological Engineering Group, the main compound fertilizer, slow release fertilizer, water soluble fertilizer, bio-fertilizer, soil conditioner, etc. required for a full line of soil and - with another giant fertilizer industry enterprises farming solutions services. 2016, Kim Jong large group with my company, to buy one of two 10 tons of steam condensing 0 5-1ton industrial steam boiler (WNS10-1.25-Y.Q). It is the product side were quick constant pursuit of quality, in-depth research and development of control and intelligent control, boiler energy efficiency as well as high demand for continuous improvement of energy efficiency and emissions, making the fertilizer industry's two leading companies invariably choose the fast way hand in hand!