No Pollution Electric Steam Boiler Price
Preparation (1) of the no pollution electric steam boiler price before use, the operator must understand how this boiler, location, performance and working methods of the various accessories. (2), check the oil combustion, and each nozzle connection, power supply and the burner, the pump, the boiler installation accessory. (3), a clear main steam valve open, after closing the normal close it. (4), water level gauge inspection, confirmation flexible water level, normal position. (5), the pressure regulator is properly tuned, regulate combustion damper.
Electric steam boiler before the preparatory work needs to be done to prepare the working electrode is a kind of steam boiler power for energy conversion from electric energy into thermal energy, the hot water or organic heat medium (HTF) is heated to a certain portion of the boiler through the heat exchanger parameters (temperature, pressure) and externally output has a nominal thermal Machinery working fluid. The use according to electric boiler can be divided into: KS-D electric water boilers, CLDR (CWDR) electric water boiler (including an electrical heating bath boilers and electric boilers), LDR (WDR) no pollution electric steam boiler price. Steam boiler is the production of specified parameters and quality of steam boilers. Quasi-electric boiler steam preparation work needs to be done to prepare one thousand work (1), the operator must understand the working principle of the boiler, location, performance and working methods of the various accessories. (2), check the oil combustion, and each nozzle connection, power supply and the burner, the pump, the boiler installation accessory. (3), a clear main steam valve open, after closing the normal close it. (4), water level gauge inspection, confirmation flexible water level, normal position. (5), the pressure regulator is properly tuned, regulate combustion damper.
Still 8 cultural and creative industrial park is located in the Chaoyang District, Beijing, Bali Zhuang Chen Lin, No. 2, construction area of 493,300 square meters. Surrounded by quintessence of Court, Red Sandalwood Museum, Shanxi Museum and other famous attractions. Due to its special geographical location, has very stringent requirements for providing heat boiler plants. Carefully selected to finalize cooperation with our company, signed a two He Lide series complete condensation pressure hot water boiler.
Gas-fired steam boiler 5 important protection mechanism, you have mastered it gas steam boiler is the main driver of industrial production and daily life provide hot water for enterprises, to buy long life, high efficiency heat transfer, high cost of gas steam boilers, is very important. To ensure the long life, from the boiler manufacturing, installation, operation and post-conservation measures start. Today, we talk about focus, gas steam boiler 5 important protection mechanism is to protect your boiler plant by what really works. 1, when the high temperature protection dry protection when the furnace temperature is detected to exceed 95 ℃, immediately cut off the heating power supply pipe, to prevent further increase in temperature. 2, when the system detects leakage protection when the leakage current exceeds 15mA, will immediately cut off power to prevent electric shock to human exposure; while the display prompts and warnings fault code, troubleshooting, restart the controller can continue to work normally. 3, when the antifreeze function in case of power control, start antifreeze function when the detected temperature is lower than 3 ℃, start heating heater; when the detected temperature is increased to 8 ℃, the heater stops heating. 4, set the boiler on various parameters of recording and saving functions are automatically recorded and saved, even if it is cut off the power supply does not need to re-set. When the time is set gas steam boiler is completed, the power-down can also be run as usual, do not correct the time after power again. 5, the temperature control function is not set if the operating temperature of the power, the system will work in accordance with a default parameter setting 50 ℃; if the set temperature, the set temperature of the press run. When turned on, the controller detects that the heating temperature is lower than the set temperature 8 ℃, by setting the gear, turn the heating tube, the heating temperature when the detected temperature is equal to higher than the set power off, stop heating. The temperature was slowly lowered to open again below the set temperature 8 ℃ heating tube, and so on, to achieve the purpose of temperature control.