2 ton coal fired steam boiler for industrials
Should be fitted with a rear quarter, oil-fired boilers at least one proof biomass boiler fuel wide variety of sources of renewable energy, green, it contains little sulfur, the fuel should be a checksum less ash pan, which is capable of absorbing growth process produces combustion all CO2, to achieve zero CO2 emissions. Biomass energy will gradually replace coal, one of the main energy sources. Biomass comprising a rear quarter straw, wood branches, wood processing waste, grain husks, shell furnace fitted with at least a sugar residue, diesel and the like. Its shape and size can be divided into chips (3mm), bar (> 50mm) form three. I since 2003, with 16 domestic well-known institutions of higher learning with the boiler pressure should be less than the rated steam temperature corresponding saturation pressure. Often is to control the pressure inside the drum safety valve should stabilize production plant requirements or by pressure "Steam Boiler Safety Technology Supervision" provided at least once every school setting and inspection. Thermometer: school inspection and maintenance comply with national metrology temperature measuring instruments. After a quarter should be fitted with a checksum at least once. Blowdown: discharge (see Section sewage) Normal operation: normal combustion conditions in the furnace should increase is flat seam necessary thickness of the fire bed. Iron grate into the furnace should not burn when the boiler load lower than the ring. Together, absorb advanced technology counterparts at home and abroad, the gradual development of biomass boilers, and continue to improve in practice in the operation, currently has a mature and stable technology, oil-fired boiler products are widely used.
Overview of 10 Ton Gas Fired Steam Boiler
10 ton gas fired steam boiler for sale in ZG Boiler is a “D” type double drums water tube boiler, and its furnace hearth is adopted with membrane water wall structure. The 10 ton gas fired steam boiler has a good fuel application, such as light oil, heavy oil, natural gas, liquefied gas, city coal gas and so on. And it has the following advantages: compact structure, small occupation area, good degree of flame; Good thermal insulation performance; With automatic burner, high combustion efficiency; Multiple protection function, safe and reliable operation; ISO9001-2008, IBR and ASME certifications.
1 ton gas boiler running on natural gas cost calculation users in the purchase of boiler equipment, in addition to considering the quality and price of the boiler, operating costs are also most concerned about. As a large industrial boilers special equipment, operating costs after start-up is not low. Today, small series to calculate the running costs of natural gas boiler, to help you better understand the gas boiler. On the whole, operating costs including natural gas boiler: fuel costs, utilities, labor costs, maintenance costs. Run 1 ton gas 2 ton coal fired steam boiler for industrials 1 hour example to calculate the cost of running the boiler. 1, the cost of gas, 1 tons of gas steam boiler steam rated the amount of 1 ton / hour, different in different parts of the integrated natural gas quality and other factors, natural gas consumption in the 70-80 cubic meters / hour, according to our understanding, now on the market of natural gas the price of 3.5 yuan / cubic calculated (prices slightly floating), gas consumption is calculated according to 75 cubic meters. Gas Cost: 1 × 75 × 3.5 = 262.5 / hour 2, the cost of water, gas steam boiler 1 tons an hour to convert 1 ton 1 ton of steam into the water, because the middle of demineralized water and sewage water treatment needs, 1 ton of normal use of the steam boiler takes about 1.1 tons of water, according to our understanding, the market price is now floating around 3 yuan / ton. The cost of water: 1.1 × 3 = 3.3 yuan / hour 3, the cost of electricity, the main fuel gas steam boiler 1 ton electric burner position and pumps, other mostly weak. Burner using power 1.5KW, use the pump power of 1.4KW, other weak power use of about 1KW. During normal use of the boiler, electrical power is 0.65 times the full load power, calculate the total electric power (1.5KW + 1.4KW + 1KW) × 0.65 = 2.535KW. The electricity is $ 1 / calculation. Electricity costs: 2.535 × 1 = 2.535 / hour 4, labor costs, fast boiler into gas boiler market is the intelligent automatic high boiler plant, only coal fireman who patrol back and forth without the need to manually add fuel high intensity work. Fireman who according to 3000 yuan / month wage, working 12 hours a day, in two shifts. Labor costs: 3000 × 2 times / 30 days / 24 h = 8.33 yuan / 5 hours, gas boilers, and maintenance costs of model SZS fast WNS square type gas boiler in the factory after the quenching treatment and a full range of testing, failure rate Very low, response, post-boiler maintenance costs are reduced. If it is a gas station one ton steam boiler, the maintenance cost is about 2000 a year on it. According to 365 days a year, eight hours a day of computing time, the boiler operation cost per hour is: 2000/365/8 = 0.68 yuan. Combining these five aspects of the cost of inputs, it can be summed up 1 ton operating cost per hour of gas boilers: 262.5 yuan / hour + 3.3 yuan / hour +2.535 yuan / hour +8.33 yuan / hour +0.68 yuan / hour = 277.345 yuan / hour . In addition Xiao Bian also like to remind you that the above calculations are based on the cost of using boiler operating at full capacity, but due to the use of the boiler boiler enterprises have different needs, it may not be fixed to keep running at full capacity. Therefore, some of the actual running costs of the boiler than it is now calculated 277.345 yuan low. If you have more questions about natural gas boiler in the running cost, please direct online consultation fast boiler for more details boiler equipment!
Recently, Taiyuan, Shanxi Province Environmental Protection Leading Group issued a circular on promoting the transformation of ultra-low emissions and low nitrogen transformation of biomass boilers gas-fired boiler. Resolutely implement - the latest requirements "2018 in Beijing, Tianjin and the surrounding areas in 2019 autumn and winter tackling air pollution comprehensive management action plan" in, and further reduces boiler emissions standards.
1, 2019 until October 31, the use of boiler tail decoration efficient dust removal, desulfurization, stock device is accomplished ultra-low emission biomass boilers transformation of the necessary funds by the counties (cities, districts) and users together to solve, not the municipal finance I grant.
2, October 31, 2019 update for ultra-low emissions of nitrogen gas boilers, electric boilers biomass boilers, municipal finance one-time grant 30 yuan / square meter construction costs, in part by the lack of counties (cities, districts) and user common solutions.
Way: by transformation to replace the low NOx combustion, a flue gas recirculation device installation mode, NOx emission is less than 30 mg / m item.
NOx emission cuts ≥50%, and the concentration value of less than 30 mg / cubic meter project, to give up prize money of 30% in accordance with the transformation of investment.
3, after December 31, 2017 the new gas boiler, should meet the emission requirements on Taiyuan low NOx combustion, but does not enjoy the low NOx combustion subsidies.