2019 small gas fired steam boiler
The main function is to ensure that the monitoring system burner safe and stable operation, the main components are: flame detectors, pressure monitors, temperature monitors and the like. Flame detector: monitoring conditions for forming the flame, and generates a signal reporting programmer. There are three main flame monitoring: photosensitive resistance, electric eye UV ultraviolet, ionizing electrode. Pressure Monitor: generally used for a gas burner, the main high-pressure gas, low voltage detection, and detecting elegant, if burner for 2019 small fired steam boilers, and steam pressure monitoring. Detector Temperature: monitoring and controlling the temperature of fuel (heavy oil).
School education is the foundation for development of our country, to provide environmental and healthy living environment for students is our top priority school. Winter is fast approaching, fast boiler heating and for us to solve the problem of the coexistence of environmental protection, give us tremendous help provide heating in winter. --customer feedback
The WNS series oil and gas 2019 small fired steam boiler is a fire tube product offering with the burner and low NOx emission, a wide range of size, pressures and premium control packages. The front head routes the flue gases from the third pass to the fan and burner assembly for reliable low NOx performance. The high performance burner assures maximum NOx reduction at all firing rates while maintaining top of the line boiler performance.
Method for safe operation of 2019 small fired steam boilers steam boiler before use, must be checked for damage of the insulating layer, to check the burner is operating correctly, and to check the position of the opening degree of the valve to ensure it is correct. Must be checked for automatic control instruments and equipment safety equipment accessories, equipment, in order to comply with the requirements. Check item prior to ignition of the steam boiler: open valve before oil circulation pump, oil heating valve is opened, adjusted reasonably high level of the tank, the gas pressure is determined before the natural gas burner ignition must be within the range, the power good . Refers to the operation of the steam boiler is refluxed pressure activated device circulating pump, the circulating pump outlet, inlet, outlet, and the system, it is in the normal range. Circulation pump run for 30 minutes. After the stability of the system, the next step. Open the gas tube steam boiler manual valve, button start-up burner, natural gas burner into the furnace, and then the ignition, the flame remains stable, i.e. is in a safe operating condition. In the firing process steam boiler, if you accidentally quenching phenomenon occurs, the device will automatically interlock burner saver appear. It must be promptly cut off the natural gas pipeline to start the furnace purification. Replacement of the residual gas in the furnace and closed. The system load requirements, temperature requirements and thermal oil outlet, the burner can automatically adjust the size of the fire source.