5000kg oil fired steam boiler
Inner Mongolia Erdos special prosecutor with the Office of the State Administration of the market, the special work of investigation and remediation of pipe hidden within the scope of the power station boilers, special inspection and testing by personnel with the Ordos Municipal Quality Supervision Bureau, Inner Mongolia Academy of pot seized the relevant professional and technical personnel , fully operational.
According to "Boiler Safety Technology Supervision", "Boiler Inspection Rules," "Boiler periodic inspection rules" and other relevant standards, conduct a special inspection of the boiler design, manufacture, installation, use, management, and inspection and other aspects. Check not extended key subject of boiler tubes, means for producing a combination of elements not subject supervisor embodiment, boiler tubes mounted QA aspect, there are security risks flow meter housing and rescue drills and contingency plans.
For risks and problems found in the inspection, and the enterprises need before the prescribed date, timely rectification results submitted to the local special equipment safety supervision and management departments.
To get industrial gas boiler safe operation must be done to check the work of industrial gas-fired boiler pressure vessel belongs, in our country there are strict and clear standards of production and operation. In particular boiler in operation, should always pay attention to whether the safe operation of the boiler, auxiliary equipment and operation of each respective instrument valves is stable. Therefore, gas 5000kg fired steam boiler room is necessary to establish a sound system of inspection tours and boiler room equipment maintenance system. First, natural gas boiler room mobile inspection system 1, in order to ensure the normal operation of the boiler and its accessory equipment, timely detection of problems, fireman on duty personnel at least once every half hour tour inspection. 2. Check gas boiler burners, pressure gauge, thermometer, circulation pump, water supply pump, water softening, safety accessories, an instrument, secondary instrument is functioning properly. 3, check whether the abnormal changes in various types of signal lights. 4, check the water level in the tank gas boiler, feed pumps, circulating pump and motor bearing temperature and pump lubricating parts are normal. 5, check the position of the gas valve and the steam boiler feedwater pressure switch valve is normal. 6, mobile inspection found problems in time, and test results recorded in the log boiler and accessory equipment inside. Second, gas-fired equipment maintenance system 1, two gas-fired boiler on the pressure gauge value is not the same timely maintenance, to ensure reflect the actual operation of the boiler pressure. 2, gas boiler pressure gauge damage, when the dial is not clear, timely replacement. 3, rotating machinery lubricating oil passage remains open, the oil cup to maintain a certain oil level. 4, run, run, drip, leak repair valves can be repaired, replaced. 5, inspection, maintenance and feed pumps, circulating pumps and pump valves open is flexible, single-stream if the door is closed tight. 6. Check the gas-fired secondary instrument is normal. 7, to remove dust on the equipment and the accessory device. 8, check the gas boiler safety valve manually turn on the water after closed trials are tight. Automatically turn on the water, blowing off steam at least once a week. 9, pressure gauges operate properly flushed at least once a week. Trap maintenance once a month. 10, over-temperature, overpressure alarms, overpressure interlock device checks at least once a month, and maintenance. Gas boiler pressure gauge, water level gauge and a safety valve are the three safety accessories on the gas steam boiler, with particular attention.
Oil-fired boilers include oil-fired water boilers, oil-fired hot water boilers, oil-fired heating boilers, oil-fired bath boilers, oil-fired 5000kg fired steam boilers and so on. Oil-fired boilers are boilers fueled by light oil (such as diesel oil, kerosene), heavy oil, residual oil or crude oil. Oil-fired boiler, gas-fired boiler, electric heating boiler is more economical than electric heating boiler and more convenient to use than gas-fired boiler compared with vertical oil-fired hot-water boiler.
WNS2-1.25-Y / Q boiler What does this mean? Boiler models are more familiar with the customer, the purchase of Zheng pot gas boilers, will directly inform the model, but many customers only know about the parameters, do not know what type of boiler Yes. The following boiler factory in Zhengzhou on demand for larger WNS2-1.25-Y / Q boiler, for example, talk about the letters and numbers represent what it means. WNS2-1.25-Y / Q boiler. 1, WNS meanings, W: horizontal, N: the internal combustion type, S: water tube boiler WNS is represented as the horizontal internal combustion boiler water tube boiler, WNS can see that the boiler is determined Cheng pressure industrial boilers, industrial boilers is with a certain pressure, but that pressure boiler CWNS, with no pressure. Zheng pot boilers are produced under pressure industrial boilers, hope buyers understand that. 2, numeral 2 represents the meaning type of desired amount of steam of 2 tons of steam / h, which is a 2 tons of steam produced hour. The boiler 5000kg fired steam boiler, can be used for the production of steam, high temperature sterilization lamp, of course, some need both for hot water or steam also requires heating customer will purchase steam boiler. 1.25 is the nominal steam pressure, which is the boiler pressure is 1.25MPa. Furthermore, it was expressed in kilograms vapor pressure expressed in units of kg / cm2.1N / m2 = 1Pa1kg = 9.8N1m2 = 10000cm2, so 1kg / cm2 = 98KPa = 0.098MPa, approximating that 1MPa = 10kg / cm2. WNS2-1.25-Y / Q boiler. 3, Y / Q meanings, Y represents a fuel oil, i.e. fuel of the boiler is a boiler; Q denotes a fuel gas, which is expressed as the boiler gas boiler; Y / Q indicates that the boiler can be either fuel gas. Through the above explanation, we can know WNS2-1.25-Y / Q boiler is a pressure of 2 tons WNS fuel gas steam boiler of 1.25MPa. If you want to know more boiler models, you can call the Henan fast Boiler Sales hotline: 0371-60922096, can also directly contact customer service online, we will provide you with professional boiler solutions.