10 bar gas steam boiler

Hot water boiler heating industry is our essential equipment, gas hot water boiler water provided by the party fast flotilla, high thermal efficiency direct savings on fuel costs of inputs for our company, the intelligence facilities let the boiler run more convenient and effective to reduce the labor intensity of fireman people. --customer feedback

Why hot water boiler heating more energy efficient, more environmentally friendly: generally used for heating hot water boilers, but the need to use less steam production process. Biomass boiler categories: biomass boilers Horizontal, vertical biomass boilers. Biomass gas thermal oil heaters, biomass 10 bar steam boiler, biomass hot water boiler, biomass oil furnace. Steam boiler is an energy conversion device, the energy input to the boiler fuel chemical energy, electrical energy, thermal energy and other forms of high temperature flue gas, and after converting the boiler, the steam output having a certain outside thermal energy, high-temperature hot water or an organic carrier. Because it is more energy efficient than steam boiler, more environmentally friendly. First of all, in terms of fuel consumption, hot water heating than the steam boiler heating savings of 20% to 40% of fuel, this amount is very impressive. Summed up for two reasons: First, it does not condensate and heat loss due to evaporation of the secondary, two hot water heating pipe is heated by the use of special materials, as thin as possible to meet pipeline needs, heat loss is small. Heat loss due to the steam heating pipe caused by steam leakage large.

Boiler multiple protection: (1) the integration of boiler water level to protect water level and boiler design, the appearance of more compact appearance, accurately show the actual water level in the boiler body function. Coupled with dual independent electronic water level control system to achieve ultra-low water level in the boiler, low water level automatic adjustment function, the normal water level, high water level, ensure that the boiler in a variety of unforeseen circumstances foolproof, secure home. (2) steam pressure protection ☆ pressure controller: selection of high sensitivity of the pressure controller, the pressure is high, or low levels of signal to the electrical switch, other control lines or automatic control chain protection. Common pressure controller and pressure gauge, vapor pressure overpressure alarm can cut off the burner limit is reached; the pressure controller may be single or double fire burning fire the actual operating pressure regulator. ☆ safety valve: safety valve is the last line of defense to protect the boiler, the boiler pressure exceeds the limit, according to the set pressure relief valve design with the school, the exhaust steam pressure relief, to ensure the normal operation of the boiler. (3) having a burner flame protection flame protection inlet means, combustion function is to detect, when the ignition failure or extinguish combustion middle, immediately off the burner into the oil (gas) solenoid valve, the blower continues to operate at this time, the furnace was purged combustible residual gas, after 20 to 30 seconds purge, and various auxiliary blowers automatically cut off power, the boiler operation stops. (4) self-locking power failure protection case, the boiler shutdown immediately burst self-locking power interruption, if the current power is restored, the boiler will not start at any time, you must reset release self-locking, to re-start the ignition.

After the gas hot water boiler hot water boiler vaporization emergency 1. Vaporization handler circulating pump stops abnormally pump failure caused by: ① blower stops running immediately. ② immediately open the door, take measures to pressure the fire, lift the chute gate, cutting off the supply of coal grate. ③ In the case of boiler pressure not greater than 0.6MPa (600KPa), the exhaust valve to follow, only a sharp rise in pressure in the boiler deflated, used only relief exceeds 0.9MPa, and the exhaust process to be carried out slowly, prevention boiler due to loss of pressure and more violently again vaporized. ④ close the boiler water, water main gas valve. ⑤ open stop valve recirculation line, to ensure that the water supply pipe velocity convection heating surface (economizer) to prevent re-vaporization of the economizer. ⑥ The operation of the above operation, at the same time to pay the boiler to reduce the boiler water temperature and the furnace pressure. ⑦ After the boiler pressure is normal, i.e., opening the standby circulating pump, into the normal combustion. 2. Treatment failure or sudden loss of power boiler vaporization of power: ① immediately open the door, lift the coal chute slide gate to take pressure fire measures to reduce the oven temperature. ② Grate with the fastest speed in order in the shortest time to fire onto the slag tap. ③ the degree of treatment in the first case. Once a short time can not supply heating network system, antifreeze should take emergency measures. 3. Due to excessive heat boiler boiler vaporization process: ① the immediate closure of the drum, induced draft fan. ② immediately open the door, take measures to pressure the fire, lift the supply of coal chute slide gate, off of coal, while the grate into fast gear. ③ In the case confirmed the presence of water, the boiler can supply water to the boiler body, boiler out of the water while closing the main valve. ④ Open line stop valve recirculation pump to ensure water velocity convection heating surface of the pipe, to prevent the economizer again vaporized. ⑤ Open circulating pump with jog mode, jog each time less than 30 seconds, again less than one minute jog interval. Jog purpose is to reduce the boiler water temperature, while preventing a large amount of steam into the pipeline system. ⑥ back into place after the safety valve, circulating pump running, and then the normal burning stove. 4. Water boiler system run vaporization process due to water loss, loss of pressure caused by: ① immediately closed drum, induced draft fan. ② out of the water while closing the main valve and the boiler circulating pump. ③ take the same measures to cool the furnace tube described above. ④ Open stop valve recirculation line. ⑤ rely exhaust valve until the safety valve back into place. ⑥ until the boiler water temperature drops below 50 ℃, when the temperature of the furnace temperature less number 200 ℃, again within the boiler feed water, water course to be carried out slowly, to prevent harm to the boiler when the temperature is too large. ⑦ After processing leakage fault, the system time to the replenishment, and out of the water boiler always open the valve, and the circulating pump, and then normal combustion.

10 bar gas steam boiler Related Information

Gas Oil Steam Boiler Manufacturer

biogas fired thermal boiler 10 bar for oil refinery biogas fired steam boiler for garment factory Electric The fuel used in the 3 ton fire tube steam boiler ordered by the Vietnamese garment factory is biogas with a pressure of 10 bar. Oil Gas Fired Boiler, Oil Gas Fired Boiler Products, Oil The thermal []

Prinsip Kerja Boiler - Teknik Membuat Steam Lebih Panas

Boiler Rating Berdasarkan tekanan, boiler dibagi menjadi tiga kelompok yaitu: Low pressure boiler (<10 bar) Medium pressure boiler (10-50 bar) High pressure boiler (>50 bar) Boiler dengan pressure lebih tinggi akan menghasilkan steam yang lebih panas.

Steam Boiler LOOS Universal ZFR-28000, 28 tons/h, 10

Steam Boiler LOOS Universal ZFR-28000 28 tons/h 10 bar Two steam boilers made by LOOS in 2004. The boilers are identical, only working hours are different. Boilers are three-pass, double-flame smoke tube boilers with separate smoke gas passages and it is also suitable for operation with only single firing. The burners are Weishaupt RGL 70/2 - A type multifuel (natural gas and light fuel oil

Steam Boiler LOOS Universal ZFR-28000, 28 tons/h, 10

Steam Boiler LOOS Universal ZFR-28000 28 tons/h 10 bar Two steam boilers made by LOOS in 2004. The boilers are identical, only working hours are different. Boilers are three-pass, double-flame smoke tube boilers with separate smoke gas passages and it is also suitable for operation with only single firing. The burners are Weishaupt RGL 70/2 - A type multifuel (natural gas and light fuel oil

Gas/Lpg/Oil Boiler, Steam/Water Boiler

2020-6-8 · Gas/lpg/diesel/oil steam boiler / hot water boiler Capacity: 100kg-50tons; 100kw-35000kw; 10hp-3000hp Aavailable fuel: Natural gas, lpg, oil, diesel, heavy oil, exhaust gas, dual fuel

boiler 10 bar - Boiler In India Steam Boiler In India

Solved: Water Enters A Boiler At 20 OC And 10 Bar And Is I Solved: Liquid Water Is Fed To A Boiler At 24°C And 10 Bar Steam Boiler VIESSMANN 10 bar 4 tons/h JADE.FIТТ115 (10 bar 110 °C) / HOT WATER BOILERS / ENTROPIE Boiler Ratings Spirax SarcoA boiler is rated at 3 000 kW (kJ/s) and operates at 10 bar g with a feedwater temperature of 50°C.

Gas/Lpg/Oil Boiler, Steam/Water Boiler

2020-6-8 · Gas/lpg/diesel/oil steam boiler / hot water boiler Capacity: 100kg-50tons; 100kw-35000kw; 10hp-3000hp Aavailable fuel: Natural gas, lpg, oil, diesel, heavy oil, exhaust gas, dual fuel

Industrial Oil Gas Steam Boiler price

Office:Numbe 33 Of Hanghai Road Zhengzhou City,Henan Province,China. Factory:Xihua County,Henan Province,China +86 150 9345 0119 +86 -150 9345 0119

Gas Fired Boiler Specification - Bharat Heavy Electricals

2013-8-27 · 1 Ton Gas Fired Boiler SPECIFICATION NO. EP-WEX-GFB/2013-14 Page 6 of 7 INSTRUMENTATION 1 Water level controllers 2nos For feed water operation and low water level alarm 2 Over-ride controller 1no for lock-out under extra low water level alarm 3 Steam pressure gauge with cock 1no For display of boiler steam pressure

Diesel Fired Wet Back Steam Boiler - Oil/Gas Fired

The diesel fired wet back steam boiler is horizontal type fast assembly fire tube boiler with three pass structure, it has compact structure, small volume, strong load adaptability and low water quality requirement This boiler adopts wet back structure, it can adapt to the high temperature, has a good sealing, increase the radiation heat transfer area and improve the heat transfer efficiency

Steam boiler Bahr'12 OR BAHR'12 Unical AG S.p.A.

High pressure steam boiler, three pass reversed flame, smooth pipes with turbulators, 90% efficiency (1). BAHR12 is a family of packaged smoke tube steam boilers, three pass reversed flame, wet back. Standard safety pressure up to 12 bar (higher pressure available on

10 bar 10 t/h Gas Steam Boiler Indonesia- Boiler

2020-6-2 ·  is a preeminent boiler manufacturer and supplier, supplying various fuels boilers with a wide range of capacity from 1 ton/hr to 400 ton/hr.We have fire tube gas oil boiler and water tube gas oil boiler. The 10 ton gas fired steam boiler can be used in: Medicine, chemical, light industry, textile, building material, cultivation, food and beverage, plastic foam, printing, dyeing and washing

Steam boiler Bahr'12 OR BAHR'12 Unical AG S.p.A.

High pressure steam boiler, three pass reversed flame, smooth pipes with turbulators, 90% efficiency (1). BAHR12 is a family of packaged smoke tube steam boilers, three pass reversed flame, wet back. Standard safety pressure up to 12 bar (higher pressure available on

Steam Boiler JADE.FI

Steam Boiler Vitomax 200 HS, capacity 16 t/h at 13 bar, year 2005 # 7452019. Good condition 16 ton/h steam boiler with dual fuel burner, made by Viessmann in year 2005. Steam Boiler LOOS ZFR-2800 28 tons/h 10 bar - 2 units # 5162017. Two good condition double flame multifuel steam boilers in very good condition and low hours

factory price 10 bar pressure 10 ton coal fired steam

China Gas Boiler manufacturer, Steam Boiler, Coal China Gas Boiler supplier, Steam Boiler, Coal Boiler Manufacturers/ Suppliers - Henan Yuanda Boiler Corporation Ltd. Factory Price 1 Ton 2 Ton 3 Ton 4 Ton 5 Ton 6 Ton 8 Ton 10 Ton 15ton 20 Ton Steam Boiler FOB Price: US $35,000 / Set 1 Ton 2 Ton 4 Ton 6 Ton 8 Ton Per Hour Capacity 12 Bar Pressure Coal Fired Steam Boiler Min. Order: 1

Related Information